| TDS/PDS--C. Qualification Criteria--
|
Tenderer shall have the following minimum level of supply experience to qualify for supplying the Goods and related services under the contract:
A) General experience for supply and installation of lift of five (05) years.
B) Specific experience of successful completion in supply, installation, testing &
commissioning of lift of
minimum value 189.00 Lac Taka in a single agreement in any Govt. /semi
govt./autonomous/private
organization within last five years (from the date of IFT) for single lift
C) The minimum supply and/or production capacity of Goods is/are: 02 (TWO) No. Lifts
per Year.
D) Every Tenderer Should Follow These Following Special Required Terms and Conditions
of Lift:
1. The bidder shall submit the technical proposal of Lift items with sealed & signed by
manufacturing company on their Letterhead pad and main catalogue (marked) including
mentioning brand, model & country of origin of the proposed lift.
The Bidder must provide the following documents as a proof of “Country of Origin”
(a) Lift Manufacturing experience of the Manufacturer Originated in USA/Europe/Japan a
Period of not less than 65 years.
2. The bidder shall submit a certificate issued by manufacturing Company stating the time
span of Lift manufacturing experience of the manufacturer. The certificate must be
authenticated by chamber of commerce/Ministry of Commerce/Ministry of foreign Affairs of
Lift manufacturing Company. The bidder shall submit the detail address of the factory,
telephone no., website address, e-mail address and company profile of the lift
manufacturing company.
The Bidder must provide the following documents as a proof of “Country of Manufacture”
(a) Lift Manufacturing experience for a period of not less than 25 year in its particular
manufacturing plant where proposed brand of lift will be manufactured.
3. The proposed lift manufacturing company shall have it's own testing tower and R&D
(Research and development) wing/centre, related document to be submitted with tender.
4. The bidder shall submit a certificate by manufacturing company stating that minimum
1000 Nos. of the proposed brand of lift have been used in minimum 10 (ten) countries of
the world including the manufacturing country for equal to or more than ten years. The
certificate must be authenticated by Chamber of Commerce/ Ministry of Commerce/
Ministry of Foreign Affairs of the lift manufacturing company.
5. EN 81 related certificates (EN 81-20 & EN 81-50, EN-81-77 for all types of lifts, EN 81
72:2015 for firefighter's lift, EN-81-31:2010 for Cargo lift) or its latest edition and Standard
test certificates, Certified Test Certificates and Type Test reports (not older than 5 years),
ISO certificates for management, occupational health and safety standard certificates,
Environmental safety certificates obtained by lift manufacturer shall be submitted by
Tenderer.
6. Each bidder must be the Sole agent /Representative / Distributor of the lift brand
proposed in the tender and the bidder must submit its all valid supporting documents
issued by original manufacturing company. Manufacturer’s certificate stating that the
bidder has sufficient trained and experienced manpower to install, test and commission the
lift as per EN 81-21 code and relevant standard and conformities.
7. The bidder shall have B, C class contractor license provided by the electric licensing
board. After completion of the work, the bidder and the manufacturing company shall
provide the certification about installation, testing and commissioning of the lift and as built
drawing of hoistway and machine room.
8. The bidder shall have one year's experience of maintenance of minimum 20 nos of lift
and a detailed list of that experience shall be certified in a prescribed form and attested by
the concerned Executive Engineer of EED.
9. The bidder shall give the assurance from the manufacturing company to supply of spare
parts for minimum 20 years and this assurance must be authenticated by the Chamber of
Commerce/ Ministry of Commerce/ Ministry of foreign affairs of the concerned
manufacturing company.
10. The bidder shall submit a certificate by manufacturing company stating that they
manufacture PMS (Permanent Magnet synchronous) type gearless motor , Polyurethane
coated steel belt & Regenerative drive (in required cases) , controller , inverter ,
motherboard , Door Inverter & all PCBs ( Printed Circuit Boards) in their own factory . The
certificate must be authenticated by Chamber of Commerce / Ministry of Commerce /
Ministry of Foreign Affairs of the Lift Manufacturing Company.
11. The block diagram of the complete lift system including all control system with
ACVVVF, power components, Regen drive (in required case) on manufacturer's letterhead
pad must be submitted with the contract.
12. The bidder shall submit a work program to complete the Lift supply and installation
work and submit a statement that before opening LC, they shall get selection of Lift items
from Procuring entity prior to manufacturing.
13. The successful bidder must submit the detail packing list with sealed and signed by the
lift manufacturing company to the concerned Executive Engineer (EED) minimum 15 days
before shipment and Lift equipment shall be listed packet wise in detail. That packing list
must comply the items described in the agreement and as per selection. The manufacturing
company must certify that all parts/items are supplied in the packing list. The name of the
project and LC no. shall be marked clearly in the packets. Equipment of one contract
cannot be packetized together with other equipment/ other contracts.
14. Before shipment, Factory Acceptance Test (performance test of safety devices of lift
and Quality assurance tests of the products as per standards) shall have to be carried out
by the manufacturer in presence of nominated engineers of EED at the lift manufacturing
factory premises. One engineer will be nominated for one lift. For two lifts in a single tender
minimum one engineer will accomplish this inspection and testing. For more than two lifts
in a single tender, the number of nominated engineers will be increased by one per two lifts.
All cost related to engineers' travel, food, accommodation, etc. will be borne by awarded
organization/Manufacturer. The expenditure for this will be incorporated by the bidder at
the time of participation. For special reasons if inspection is not performed by the
engineers of the EED, taking prior approval of the procuring entity quality assurance tests
will be carried out by Internationally accepted inspection agencies(home and abroad).
15. Post landing inspection for imported lift(s) shall be done by representatives of
Procuring Entity according to the packing list and the expenditure for it will be carried out
by Contractor /Supplier. After post landing inspection from the port, the imported
equipment shall be reached directly to the project site according to the condition of the
contract.
16. The bidder shall certify that all given certificates/ documents/ drawings are complete
and correct. If any error is found, the contract will be cancelled and the bidder will be
disqualified from future participation of any tender.
17. Maintenance engineers of the tenderer must receive service level 1-2-3 certification,
employees of them must receive quarterly training
18. Yearly Confirmation of Periodic Safety Inspection (CPSI) must be done on full portfolio
of the tenderer organization and yearly technical clarification audit must be done with
mother company/Principal
E. Details Technical Specification of 1000Kg Passenger Lift are Below:
I. Type : Gearless, oil free, permanent magnet synchronus motor driven type Passenger
Lift .
II. Capacity : 1000 Kg. (13 Passengers)
II. No. of stops : 6 Stops
IV. Travelling speed : 1.0 Meter per second.
V. Car Travel height : 21 Meters (Approximate)
VI. Floor Designations : G, 1,2,3,4,5
VII. Power rating : Compatible with the capacity of the lift as mentioned above with 180
starts per hour minimum.
VIII. Number of entrances : one arranged in the same line.
IX. a) Shaft size : 2200 mm (Width) x 2300 mm (Depth)
b) Cabin size : 1500 mm (Width) x 1600 mm (Depth) x 2400 mm (Height)
c) Door size : 1000 mm (Width) x 2100 mm (Height) [Center opening(CO)]
d) Machine Room Dimension: 2300 mm x 4000 mm
X. a) Pit depth : 1600 mm.
b) Overhead Height : 4600 mm
XI. Machine room location: Directly Above Hoist Way.
XII. Power source : 400 Volt. (+10%), 3-Phase, 50Hz.
XIII. Light mains : 230 Volt. (+10%), single-phase 50Hz.
XIV. Signal source : 24 volt. D.C or as designed.
XV. Operation System : Simplex
XVI. Control system : Collective selective with fully programmable microprocessor control,
BMS compatible, designed for optimum, efficient & energy saving elevator operation. All
controls shall always be equipped with an alarm device in machine room, control room and
other suitable places as per direction of the Engineer-in-charge. Variation in speed of the
lift between no load & full load conditions shall not be more than +/- 10%. The control
system shall be capable of correcting any tendency to over speed or under speed, shall
have safety devices to stop the car if it's running speed exceeds it's rated speed by 20%.
The car stopping & leveling system shall be unaffected by external influence like variation
in load, temperature and rope elongation etc. There shall be enhanced protection
mechanism to address the risk of the car moving away from the landing and the
requirement for protection against ascending car overspeed.The drive control system with
Thyristor/ IGBTs (Integrated Gate Bipolar Transistors) controls acceleration & deceleration
getting feedback from encoder and shows information & data in LED display. The
controller must be manufactured as per drawing & design by the proposed Brand of Lift
manufacturing company.Test certificate of the control system shall be furnished during
execution of work.
XVII. Additional controls & accessories : " Additional controls & accessories :
* Over load control with indication lamp & buzzer/indication & buzzer.
* Full load control with indication.
* Attendant control.
* Fire man’s control switch at ground floor.
* 3 station, (2-way) inter-communication system between the car, machine room & other
suitable place.
* Door close / open button in the car.
* Sensor switch in the car for light & fan.
*Line flow Fan fitted on drop ceiling for sufficient air flow. * Water detection system in Lift
Shaft pit"
XVIII. Maintenance control : Car stop station with :-- An initiation switch.- One up & down button.- One stop button.
XIX Traction Machine : "Gearless, oil free, permanent magnet synchronous motor (Class of
insulation : F) which must be manufactured as per drawing & design of the lift
manufacturing company.
"
XX Drive system : " Inverter operated A.C. Variable Voltage, Variable frequency (AC-VVVF)
drive system with the following features:
* Microprocessor based steepless controlled, electronically regulated during acceleration &
deceleration with floor approach.
* Electromagnet operated holding brake to be applied only after the car comes to a stand
still.
* The capacity of the VVVF drive shall be minimum 20% higher than the optimum full load
capacity of the driven motor of the lift.
* The microprocessor shall be of adequate bit data processing industrial class controller
for commercial/residential/hospital/observation lifts, with CAN bus serial Communication
mode, suitable for 0.63-4.0 m/s elevator speed for synchronous /asynchronous traction
motor, having analog/digital and multi speed function, load weighing compensation
function, strong electromagnetic/ electrostatic anti-Interference ability.
* The entire control system of the lift shall be designed and manufactured in such a way
that appropriately synchronizes the whole system.
* Test certificate of the drive system shall be furnished by Contractor during execution of
work.
"
XXI. Smooth leveling : The lift shall be provided with automatic self leveling feature to
ensure automatic aligning the car with the floor landing within a tolerance of (+/-) 5mm
under normal loading & unloading conditions. Self-leveling will be entirely automatic &
independent of the operating device & shall correct the over travel, under travel & rope
stretch.
XXII. CAR
a) Cabin floor : Securedly fastened sheet steel sound isolated platform made of fire
resistant and weather resistant sound absorbing synthetic materials that should be of as
standard french classification M3, i.e. fire classification requirement cfl, s2 according to
EN13501-1
b) Car frame & safety : Car body Passenger type made of entirely structural sheet steel
(304/441 grade) assembly to safely support the rated load of the cabin & accessories with
elastic isolators between metal parts to ensure low vibration & low noise during car travel
with natural ventilation arrangement in ceiling & floor
c) Car type : Made of entirely Stainless steel 304 / 441 grade for steel part and 10mm thick
tempered glass for rest of the part
d) car body & roof : The car body shall be of sufficient mechanical strength to resist
accidental impact. The roof shall be capable of supporting two persons or minimum load of
150 kg. The platform shall be made of sheet steel. The enclosure height shall be 2400mm
minimum below suspended ceiling
e)Cabin walls : The material shall be of standard as French Classification M2 i.e. fire
classification Cs2,d1 as per requirement according to EN13501-1 & it shall be 1.5 mm thick
sheet steel with 0.7mm (minimum) stainless steel sheet walls with stainless steel etching
hairline / mirror / hairline / digital print / synthetic wood /laminated wood finish in sections
having in front, rear & side walls as per manufacturer’s standard design to be to be such
that the door shall withstand under an applied load of 300N without permanent
deformation> 1mm and without elastic deformation>15mm, Under an applied force of
1000N, all types of doors shall withstand without permanent deformation >10mm . The
devices providing mechanical linkage between panels shall withstand to the force of 1000N
. A mechanical device shall prevent the door panels from disengaging from their guides .
f) Cabin door : " Fully automatic heavy duty centre/side opening horizontal sliding door
panel of stainless steel etching hairline/hairline/digital print finish to be such that the door
(both landing and Car doors) shall withstand under an applied load of 300N without
permanent deformation> 1mm and without elastic deformation>15mm, Under an applied
force of 1000N, all types of doors shall withstand without permanent deformation >10mm .
The devices providing mechanical linkage between panels shall withstand to the force of
1000N . A mechanical device shall prevent the door panels from disengaging from their
guides .
"
g) Car Ceiling : "Anodized metal framed with decorative stainless steel luminous ceiling by
LED light of 100 Lux in normal mode at 1m above the floor and 5 Lux in emergency mode
for 1 hour at 1m at the center of the car and near the emergency push buttons Synthetic
glass with diffused motion sensor LED lighting / any other options selected by the
Engineer in charge.
"
h) LOP & COP : "Metallic structures call button LED panel with indication system on each
landing, digital car position indicators, arrival gong & direction indicators/arrows to be
installed above or at the side of the landing doors at all landing & inside the car. Car
Operating panel board to be installed inside the car. Manual call cancellation system should
be incorporated inside lift car OPB. The center line of the hall call buttons shall be at a
nominal height of 01 meter above the floor.
"
f) Other cabin features : "3 (Three) hand rails of smooth stainless steel of minimum 100
mm. width & 12 mm thickness or 30 mm dia round shape.
* Mirror on full rear wall of car from top to hand rail.
* Re-tractable both safety shoes for the full height of the door which reopens the door
when it is obstructed by any object while closing.
* Emergency exit with safety contact in car roof, the trap door can be opened from inside
and outside the car.
* A door reversal feature in case of obstruction of door *Concealed fan(s) fitted on ceiling
for adequate forced ventilation of 20 air change per hour for Pandemic or non pandemic
situation with better ventilation (suitable for tropicalised country like Bangladesh) to create
comfortable environment for the passenger."
XXIII. Door : Door size, type and dimension will be as per data mentioned above
Doorsills : "Doorsills shall be extruded aluminum with anti-slip grooving with guiding slots.
"
Door operation : "High-speed heavy-duty ACVVVF inverter operated door operator with
adjustable speed for opening and closing. Door will be driven by quiet A.C. motor
connected to an inverter operated door operation system. Car and landing doors will be
open and close in full synchronization being connected to each other. The landing doors
will have Electro-mechanical locks. Each landing door will be provided with positive
interlock operated by a coupling on the car door and shall prevent the movement of the car
away from the landing unless both doors are closed and locked. The interlocks will be
designed to prevent opening of the door except at the landing, at which the car is stopping
or has stopped .The door closing speed shall be reduced and an audible signal notifies
users of a fault or the elevator will be stopped. A mechanical device prevents the door
panels from disengaging from their guides. Also shall have :
* Door detection system with Curtain of Light Mechanism
* Enhanced control for Lift Car Door locking system that aims to prevent the doors from
being opened from inside when the car is outside the unlocking zone.
*The door closing speed shall be reduced and an audible signal notifies users of a fault or
the elevator will be stopped. There shall be door pressure limit sensor.
*A mechanical device prevents the door panels from disengaging from their guides.
*Name of the door manufacturer to be mentioned in the door."
XXIV. Safety features : Non contact electronic full height door safety sensor, power supply,
Auto phase reversal correction, friction clutch to avoid passengers to be trapped between
doors.
a) Emergency unlocking of door from landing for evacuation as well as for maintenance
with a special key.
b) Facilities for opening of door from inside the car within the landingduring power failure
c) During power failure, Manual opening of doors from inside the car is possible within
landing zone.
d) A friction clutch to avoid passengers to be trapped between door.
e) A door reversible feature in case of obstruction of door.
f)In cases where installation of a safety hatch on the car roof is required, its dimension
shall be of minimum clear opening 0.4mx0.5m, where the toe guard shall withstand applied
force of 300N without permanent deformation>1mm and without elastic deformation>35mm.
g)The brakes shall have self checking arrangement.
h)Under an applied force of 1000N, the shaft walls shall withstand without permanent
deformation >1mm and without elastic deformation >15mm , without permanent
deformation in the case of laminated glass type walls.
i) For safety of technicians, the safety refuge at top of the shaft shall be 2.0mx 0.4mx
0.5m(HxPxL) for standing, and 1.0mx0.5mx0.7m (hxPxL) for Couching. Additional
authorised position in the pit shall be 0.5mx0.7mx1.0m (HxPxL) considering laying
condition. Car roof itself should also have an anti slip working surface.
j) Shaft lighting should provide a minimujm of 50 Lux one meter above the car roof
vertically, 1 meter above the pit floor everywhere a person can stand, work or move
between work areas and 20 lux elsewhere excluding any shadows.
k) The lift machine room should have a lighting of a minimum 200 Lux
l) Emergency lighting on the car roof must be sustained at 5 lux for one hour
XXV) Guide rails : Guide rails shall be continuous throughout the entire length right from
the bottom of the pit floor to the top most floor served, plus additional length as may be
required for smooth operation or equivalent fixing devices shall be provided which are of
such design & spacing that rails shall not deflect more than 4mm under normal condition.
The relevant fixing devices such as brackets, clamps etc shall be of such design & spacing
that rails shall not deflect more than 4mm under normal working condition. The dimension
of the guide rails (both main and counter weight guide rails) shall be as per latest version of
EN-81 standards.
XXVI) Suspension rope : "Main rope shall be of Polyurethane coated steel belt (for Lift type
A& C).
* The rope suspension is to be constructed to shut the lift down if one or more suspension
ropes become slack.
* The over Speed Governor rope shall be of bright steel wires minimum 6mm dia or as per
manufacturer's design having a safety factor at least 8."
XXVII) Speed governor & safety gear : "Gradual type safety gear actuated by the speed
governor to be installed in the machine room above the hoist way/inside the head room in
order to stop the car quickly & safely in case of exceeding 20% of designed speed during
down/up both wards travel for any reasons (i.e. breakage of all suspension elements).-Suitable means will be supplied to cut off power from the motor and apply brake on
application of the safety
"
XXVIII) Counter weight condition : Car and counter weight guide rails shall be made as per
International Standard and shall have working surface machined & smooth. There shall be
counterweight safety gear in case of floating
i)Buffer : Energy absorbing oil buffer for speed more than 1m/sec, oil/spring buffer for
speed less than 1m/sec shall be mounted in pit beneath the car & counter weight with
suitable concrete foundation
ii) Pre & Final limit switch : To disconnect the controller from electric power supply if the
car over travels higher at the top or lower at the bottom terminal landing.
XXIX) Traveling cable, wiring : Traveling cables having conductors adequate in size &
number.- All electrical cables shall be fire retardant and shall go through PVC conduits in machine
room & shaft. The circuit, wiring cable of the motor shall not run through any pipe used in
connection with the wiring for the control and safety devices.
XXX) Automatic Rescue Device (ARD) "Built-in Automatic Rescue Device set (ARD) set as
per capacity of lift set with following specification travel height : 3.5 m to 7.0 m. Drive
system : min 3 times/h and starting time after min 20 sec & max 180 sec that can be set
manually. Direction : up or down which side is heavier
Battery: Maintenance free Sealed Gelled / AGM battery or equivalent suitable for minimum
three rescue operations without recharging and complete as per direction of the Engineer
in-Charge"
XXXI). Painting : All exposed ferrous metal parts of machine, car, doors and other materials
in the hoistway including guide rail fixation brackets (except guide rails) will have one coat
of factory rust protecting paint.
XXXII). Operation and Maintenance Manuals : 4 (Four) sets of detail operation &
maintenance manuals , catalogues, spare parts catalogues with part number, control wiring
diagrams and soft copy etc. shall be included to the supply of lift & the language shall be in
English.
XXXIII). Standard /Conformity : "The entire lift shall be designed & manufactured as per
latest version of EN-81 standards, EN-81-20, EN 81-50. The safety components, such as,
progressive safety gear, door locking devices, buffers, over speed governor, car over travel
protection system, door inter-locking device, pre and final limit switches of the proposed
lift shall be in conformity with latest version of BNBC, BS EN-81/EN-81(Lift Directive
95/16/EC) / DIN / VDE / ANSI/ASME A17.1 / JIS standards & safety codes. Installation,
testing and Commissioning of the lift shall also be in conformity with the above standards
& codes.
Certificates issued by internationally recognized authorities like TUV / DNV for the
product(s) (At least the safety components such as, progressive safety gear, door locking
devices, buffers, over speed governor, car over travel protection system, door inter-locking
device, pre and final limit switches) of the manufacturer(s) as per above mentioned relevant
valid regulations, codes and standards shall have to be submitted by the bidder.
The above certificates shall have to be authenticated by the Chamber of Commerce /
Ministry of Commerce / Foreign Ministry of the manufacturing Country. Relevant ISO
certificate(s) of the manufacturer including lift ride quality measurement ISO 18738/5 shall
also have to be submitted by the bidder. |
Tenderer shall have the following minimum level of supply experience to qualify for supplying the Goods and related services under the contract:
A) General experience for supply and installation of lift of five (05) years.
B) Specific experience of successful completion in supply, installation, testing &
commissioning of lift of minimum value 63.00 Lac Taka in a single agreement in any Govt. /semi
govt./autonomous/private organization within last five years (from the date of IFT) for single lift
C) The minimum supply and/or production capacity of Goods is/are: 01 (ONE) No. Lift per Year.
D) Every Tenderer Should Follow These Following Special Required Terms and Conditions of Lift:
1. The bidder shall submit the technical proposal of Lift items with sealed & signed by
manufacturing company on their Letterhead pad and main catalogue (marked) including
mentioning brand, model & country of origin of the proposed lift.
The Bidder must provide the following documents as a proof of “Country of Origin”
(a) Lift Manufacturing experience of the Manufacturer Originated in USA/Europe/Japan a
Period of not less than 65 years.
2. The bidder shall submit a certificate issued by manufacturing Company stating the time
span of Lift manufacturing experience of the manufacturer. The certificate must be
authenticated by chamber of commerce/Ministry of Commerce/Ministry of foreign Affairs of
Lift manufacturing Company. The bidder shall submit the detail address of the factory,
telephone no., website address, e-mail address and company profile of the lift
manufacturing company.
The Bidder must provide the following documents as a proof of “Country of Manufacture”
(a) Lift Manufacturing experience for a period of not less than 25 year in its particular
manufacturing plant where proposed brand of lift will be manufactured.
3. The proposed lift manufacturing company shall have it's own testing tower and R&D
(Research and development) wing/centre, related document to be submitted with tender.
4. The bidder shall submit a certificate by manufacturing company stating that minimum
1000 Nos. of the proposed brand of lift have been used in minimum 10 (ten) countries of
the world including the manufacturing country for equal to or more than ten years. The
certificate must be authenticated by Chamber of Commerce/ Ministry of Commerce/
Ministry of Foreign Affairs of the lift manufacturing company.
5. EN 81 related certificates (EN 81-20 & EN 81-50, EN-81-77 for all types of lifts, EN 81
72:2015 for firefighter's lift, EN-81-31:2010 for Cargo lift) or its latest edition and Standard
test certificates, Certified Test Certificates and Type Test reports (not older than 5 years),
ISO certificates for management, occupational health and safety standard certificates,
Environmental safety certificates obtained by lift manufacturer shall be submitted by
Tenderer.
6. Each bidder must be the Sole agent /Representative / Distributor of the lift brand
proposed in the tender and the bidder must submit its all valid supporting documents
issued by original manufacturing company. Manufacturer’s certificate stating that the
bidder has sufficient trained and experienced manpower to install, test and commission the
lift as per EN 81-21 code and relevant standard and conformities.
7. The bidder shall have B, C class contractor license provided by the electric licensing
board. After completion of the work, the bidder and the manufacturing company shall
provide the certification about installation, testing and commissioning of the lift and as built
drawing of hoistway and machine room.
8. The bidder shall have one year's experience of maintenance of minimum 20 nos of lift
and a detailed list of that experience shall be certified in a prescribed form and attested by
the concerned Executive Engineer of EED.
9. The bidder shall give the assurance from the manufacturing company to supply of spare
parts for minimum 20 years and this assurance must be authenticated by the Chamber of
Commerce/ Ministry of Commerce/ Ministry of foreign affairs of the concerned
manufacturing company.
10. The bidder shall submit a certificate by manufacturing company stating that they
manufacture PMS (Permanent Magnet synchronous) type gearless motor , Polyurethane
coated steel belt & Regenerative drive (in required cases) , controller , inverter ,
motherboard , Door Inverter & all PCBs ( Printed Circuit Boards) in their own factory . The
certificate must be authenticated by Chamber of Commerce / Ministry of Commerce /
Ministry of Foreign Affairs of the Lift Manufacturing Company.
11. The block diagram of the complete lift system including all control system with
ACVVVF, power components, Regen drive (in required case) on manufacturer's letterhead
pad must be submitted with the contract.
12. The bidder shall submit a work program to complete the Lift supply and installation
work and submit a statement that before opening LC, they shall get selection of Lift items
from Procuring entity prior to manufacturing.
13. The successful bidder must submit the detail packing list with sealed and signed by the
lift manufacturing company to the concerned Executive Engineer (EED) minimum 15 days
before shipment and Lift equipment shall be listed packet wise in detail. That packing list
must comply the items described in the agreement and as per selection. The manufacturing
company must certify that all parts/items are supplied in the packing list. The name of the
project and LC no. shall be marked clearly in the packets. Equipment of one contract
cannot be packetized together with other equipment/ other contracts.
14. Before shipment, Factory Acceptance Test (performance test of safety devices of lift
and Quality assurance tests of the products as per standards) shall have to be carried out
by the manufacturer in presence of nominated engineers of EED at the lift manufacturing
factory premises. One engineer will be nominated for one lift. For two lifts in a single tender
minimum one engineer will accomplish this inspection and testing. For more than two lifts
in a single tender, the number of nominated engineers will be increased by one per two lifts.
All cost related to engineers' travel, food, accommodation, etc. will be borne by awarded
organization/Manufacturer. The expenditure for this will be incorporated by the bidder at
the time of participation. For special reasons if inspection is not performed by the
engineers of the EED, taking prior approval of the procuring entity quality assurance tests
will be carried out by Internationally accepted inspection agencies(home and abroad).
15. Post landing inspection for imported lift(s) shall be done by representatives of
Procuring Entity according to the packing list and the expenditure for it will be carried out
by Contractor /Supplier. After post landing inspection from the port, the imported
equipment shall be reached directly to the project site according to the condition of the
contract.
16. The bidder shall certify that all given certificates/ documents/ drawings are complete
and correct. If any error is found, the contract will be cancelled and the bidder will be
disqualified from future participation of any tender.
17. Maintenance engineers of the tenderer must receive service level 1-2-3 certification,
employees of them must receive quarterly training
18. Yearly Confirmation of Periodic Safety Inspection (CPSI) must be done on full portfolio
of the tenderer organization and yearly technical clarification audit must be done with
mother company/Principal
E. Details Technical Specification of 1000Kg Passenger Lift are Below:
I. Type : Gearless, oil free, permanent magnet synchronus motor driven type Passenger
Lift .
II. Capacity : 1000 Kg. (13 Passengers)
II. No. of stops : 6 Stops
IV. Travelling speed : 1.0 Meter per second.
V. Car Travel height : 21 Meters (Approximate)
VI. Floor Designations : G, 1,2,3,4,5
VII. Power rating : Compatible with the capacity of the lift as mentioned above with 180
starts per hour minimum.
VIII. Number of entrances : one arranged in the same line.
IX. a) Shaft size : 2200 mm (Width) x 2300 mm (Depth)
b) Cabin size : 1500 mm (Width) x 1600 mm (Depth) x 2400 mm (Height)
c) Door size : 1000 mm (Width) x 2100 mm (Height) [Center opening(CO)]
d) Machine Room Dimension: 2300 mm x 4000 mm
X. a) Pit depth : 1600 mm.
b) Overhead Height : 4600 mm
XI. Machine room location: Directly Above Hoist Way.
XII. Power source : 400 Volt. (+10%), 3-Phase, 50Hz.
XIII. Light mains : 230 Volt. (+10%), single-phase 50Hz.
XIV. Signal source : 24 volt. D.C or as designed.
XV. Operation System : Simplex
XVI. Control system : Collective selective with fully programmable microprocessor control,
BMS compatible, designed for optimum, efficient & energy saving elevator operation. All
controls shall always be equipped with an alarm device in machine room, control room and
other suitable places as per direction of the Engineer-in-charge. Variation in speed of the
lift between no load & full load conditions shall not be more than +/- 10%. The control
system shall be capable of correcting any tendency to over speed or under speed, shall
have safety devices to stop the car if it's running speed exceeds it's rated speed by 20%.
The car stopping & leveling system shall be unaffected by external influence like variation
in load, temperature and rope elongation etc. There shall be enhanced protection
mechanism to address the risk of the car moving away from the landing and the
requirement for protection against ascending car overspeed.The drive control system with
Thyristor/ IGBTs (Integrated Gate Bipolar Transistors) controls acceleration & deceleration
getting feedback from encoder and shows information & data in LED display. The
controller must be manufactured as per drawing & design by the proposed Brand of Lift
manufacturing company.Test certificate of the control system shall be furnished during
execution of work.
XVII. Additional controls & accessories : " Additional controls & accessories :
* Over load control with indication lamp & buzzer/indication & buzzer.
* Full load control with indication.
* Attendant control.
* Fire man’s control switch at ground floor.
* 3 station, (2-way) inter-communication system between the car, machine room & other
suitable place.
* Door close / open button in the car.
* Sensor switch in the car for light & fan.
*Line flow Fan fitted on drop ceiling for sufficient air flow. * Water detection system in Lift
Shaft pit"
XVIII. Maintenance control : Car stop station with :-- An initiation switch.- One up & down button.- One stop button.
XIX Traction Machine : "Gearless, oil free, permanent magnet synchronous motor (Class of
insulation : F) which must be manufactured as per drawing & design of the lift
manufacturing company.
"
XX Drive system : " Inverter operated A.C. Variable Voltage, Variable frequency (AC-VVVF)
drive system with the following features:
* Microprocessor based steepless controlled, electronically regulated during acceleration &
deceleration with floor approach.
* Electromagnet operated holding brake to be applied only after the car comes to a stand
still.
* The capacity of the VVVF drive shall be minimum 20% higher than the optimum full load
capacity of the driven motor of the lift.
* The microprocessor shall be of adequate bit data processing industrial class controller
for commercial/residential/hospital/observation lifts, with CAN bus serial Communication
mode, suitable for 0.63-4.0 m/s elevator speed for synchronous /asynchronous traction
motor, having analog/digital and multi speed function, load weighing compensation
function, strong electromagnetic/ electrostatic anti-Interference ability.
* The entire control system of the lift shall be designed and manufactured in such a way
that appropriately synchronizes the whole system.
* Test certificate of the drive system shall be furnished by Contractor during execution of
work.
"
XXI. Smooth leveling : The lift shall be provided with automatic self leveling feature to
ensure automatic aligning the car with the floor landing within a tolerance of (+/-) 5mm
under normal loading & unloading conditions. Self-leveling will be entirely automatic &
independent of the operating device & shall correct the over travel, under travel & rope
stretch.
XXII. CAR
a) Cabin floor : Securedly fastened sheet steel sound isolated platform made of fire
resistant and weather resistant sound absorbing synthetic materials that should be of as
standard french classification M3, i.e. fire classification requirement cfl, s2 according to
EN13501-1
b) Car frame & safety : Car body Passenger type made of entirely structural sheet steel
(304/441 grade) assembly to safely support the rated load of the cabin & accessories with
elastic isolators between metal parts to ensure low vibration & low noise during car travel
with natural ventilation arrangement in ceiling & floor
c) Car type : Made of entirely Stainless steel 304 / 441 grade for steel part and 10mm thick
tempered glass for rest of the part
d) car body & roof : The car body shall be of sufficient mechanical strength to resist
accidental impact. The roof shall be capable of supporting two persons or minimum load of
150 kg. The platform shall be made of sheet steel. The enclosure height shall be 2400mm
minimum below suspended ceiling
e)Cabin walls : The material shall be of standard as French Classification M2 i.e. fire
classification Cs2,d1 as per requirement according to EN13501-1 & it shall be 1.5 mm thick
sheet steel with 0.7mm (minimum) stainless steel sheet walls with stainless steel etching
hairline / mirror / hairline / digital print / synthetic wood /laminated wood finish in sections
having in front, rear & side walls as per manufacturer’s standard design to be to be such
that the door shall withstand under an applied load of 300N without permanent
deformation> 1mm and without elastic deformation>15mm, Under an applied force of
1000N, all types of doors shall withstand without permanent deformation >10mm . The
devices providing mechanical linkage between panels shall withstand to the force of 1000N
. A mechanical device shall prevent the door panels from disengaging from their guides .
f) Cabin door : " Fully automatic heavy duty centre/side opening horizontal sliding door
panel of stainless steel etching hairline/hairline/digital print finish to be such that the door
(both landing and Car doors) shall withstand under an applied load of 300N without
permanent deformation> 1mm and without elastic deformation>15mm, Under an applied
force of 1000N, all types of doors shall withstand without permanent deformation >10mm .
The devices providing mechanical linkage between panels shall withstand to the force of
1000N . A mechanical device shall prevent the door panels from disengaging from their
guides .
"
g) Car Ceiling : "Anodized metal framed with decorative stainless steel luminous ceiling by
LED light of 100 Lux in normal mode at 1m above the floor and 5 Lux in emergency mode
for 1 hour at 1m at the center of the car and near the emergency push buttons Synthetic
glass with diffused motion sensor LED lighting / any other options selected by the
Engineer in charge.
"
h) LOP & COP : "Metallic structures call button LED panel with indication system on each
landing, digital car position indicators, arrival gong & direction indicators/arrows to be
installed above or at the side of the landing doors at all landing & inside the car. Car
Operating panel board to be installed inside the car. Manual call cancellation system should
be incorporated inside lift car OPB. The center line of the hall call buttons shall be at a
nominal height of 01 meter above the floor.
"
f) Other cabin features : "3 (Three) hand rails of smooth stainless steel of minimum 100
mm. width & 12 mm thickness or 30 mm dia round shape.
* Mirror on full rear wall of car from top to hand rail.
* Re-tractable both safety shoes for the full height of the door which reopens the door
when it is obstructed by any object while closing.
* Emergency exit with safety contact in car roof, the trap door can be opened from inside
and outside the car.
* A door reversal feature in case of obstruction of door *Concealed fan(s) fitted on ceiling
for adequate forced ventilation of 20 air change per hour for Pandemic or non pandemic
situation with better ventilation (suitable for tropicalised country like Bangladesh) to create
comfortable environment for the passenger."
XXIII. Door : Door size, type and dimension will be as per data mentioned above
Doorsills : "Doorsills shall be extruded aluminum with anti-slip grooving with guiding slots.
"
Door operation : "High-speed heavy-duty ACVVVF inverter operated door operator with
adjustable speed for opening and closing. Door will be driven by quiet A.C. motor
connected to an inverter operated door operation system. Car and landing doors will be
open and close in full synchronization being connected to each other. The landing doors
will have Electro-mechanical locks. Each landing door will be provided with positive
interlock operated by a coupling on the car door and shall prevent the movement of the car
away from the landing unless both doors are closed and locked. The interlocks will be
designed to prevent opening of the door except at the landing, at which the car is stopping
or has stopped .The door closing speed shall be reduced and an audible signal notifies
users of a fault or the elevator will be stopped. A mechanical device prevents the door
panels from disengaging from their guides. Also shall have :
* Door detection system with Curtain of Light Mechanism
* Enhanced control for Lift Car Door locking system that aims to prevent the doors from
being opened from inside when the car is outside the unlocking zone.
*The door closing speed shall be reduced and an audible signal notifies users of a fault or
the elevator will be stopped. There shall be door pressure limit sensor.
*A mechanical device prevents the door panels from disengaging from their guides.
*Name of the door manufacturer to be mentioned in the door."
XXIV. Safety features : Non contact electronic full height door safety sensor, power supply,
Auto phase reversal correction, friction clutch to avoid passengers to be trapped between
doors.
a) Emergency unlocking of door from landing for evacuation as well as for maintenance
with a special key.
b) Facilities for opening of door from inside the car within the landingduring power failure
c) During power failure, Manual opening of doors from inside the car is possible within
landing zone.
d) A friction clutch to avoid passengers to be trapped between door.
e) A door reversible feature in case of obstruction of door.
f)In cases where installation of a safety hatch on the car roof is required, its dimension
shall be of minimum clear opening 0.4mx0.5m, where the toe guard shall withstand applied
force of 300N without permanent deformation>1mm and without elastic deformation>35mm.
g)The brakes shall have self checking arrangement.
h)Under an applied force of 1000N, the shaft walls shall withstand without permanent
deformation >1mm and without elastic deformation >15mm , without permanent
deformation in the case of laminated glass type walls.
i) For safety of technicians, the safety refuge at top of the shaft shall be 2.0mx 0.4mx
0.5m(HxPxL) for standing, and 1.0mx0.5mx0.7m (hxPxL) for Couching. Additional
authorised position in the pit shall be 0.5mx0.7mx1.0m (HxPxL) considering laying
condition. Car roof itself should also have an anti slip working surface.
j) Shaft lighting should provide a minimujm of 50 Lux one meter above the car roof
vertically, 1 meter above the pit floor everywhere a person can stand, work or move
between work areas and 20 lux elsewhere excluding any shadows.
k) The lift machine room should have a lighting of a minimum 200 Lux
l) Emergency lighting on the car roof must be sustained at 5 lux for one hour
XXV) Guide rails : Guide rails shall be continuous throughout the entire length right from
the bottom of the pit floor to the top most floor served, plus additional length as may be
required for smooth operation or equivalent fixing devices shall be provided which are of
such design & spacing that rails shall not deflect more than 4mm under normal condition.
The relevant fixing devices such as brackets, clamps etc shall be of such design & spacing
that rails shall not deflect more than 4mm under normal working condition. The dimension
of the guide rails (both main and counter weight guide rails) shall be as per latest version of
EN-81 standards.
XXVI) Suspension rope : "Main rope shall be of Polyurethane coated steel belt (for Lift type
A& C).
* The rope suspension is to be constructed to shut the lift down if one or more suspension
ropes become slack.
* The over Speed Governor rope shall be of bright steel wires minimum 6mm dia or as per
manufacturer's design having a safety factor at least 8."
XXVII) Speed governor & safety gear : "Gradual type safety gear actuated by the speed
governor to be installed in the machine room above the hoist way/inside the head room in
order to stop the car quickly & safely in case of exceeding 20% of designed speed during
down/up both wards travel for any reasons (i.e. breakage of all suspension elements).-Suitable means will be supplied to cut off power from the motor and apply brake on
application of the safety
"
XXVIII) Counter weight condition : Car and counter weight guide rails shall be made as per
International Standard and shall have working surface machined & smooth. There shall be
counterweight safety gear in case of floating
i)Buffer : Energy absorbing oil buffer for speed more than 1m/sec, oil/spring buffer for
speed less than 1m/sec shall be mounted in pit beneath the car & counter weight with
suitable concrete foundation
ii) Pre & Final limit switch : To disconnect the controller from electric power supply if the
car over travels higher at the top or lower at the bottom terminal landing.
XXIX) Traveling cable, wiring : Traveling cables having conductors adequate in size &
number.- All electrical cables shall be fire retardant and shall go through PVC conduits in machine
room & shaft. The circuit, wiring cable of the motor shall not run through any pipe used in
connection with the wiring for the control and safety devices.
XXX) Automatic Rescue Device (ARD) "Built-in Automatic Rescue Device set (ARD) set as
per capacity of lift set with following specification travel height : 3.5 m to 7.0 m. Drive
system : min 3 times/h and starting time after min 20 sec & max 180 sec that can be set
manually. Direction : up or down which side is heavier
Battery: Maintenance free Sealed Gelled / AGM battery or equivalent suitable for minimum
three rescue operations without recharging and complete as per direction of the Engineer
in-Charge"
XXXI). Painting : All exposed ferrous metal parts of machine, car, doors and other materials
in the hoistway including guide rail fixation brackets (except guide rails) will have one coat
of factory rust protecting paint.
XXXII). Operation and Maintenance Manuals : 4 (Four) sets of detail operation &
maintenance manuals , catalogues, spare parts catalogues with part number, control wiring
diagrams and soft copy etc. shall be included to the supply of lift & the language shall be in
English.
XXXIII). Standard /Conformity : "The entire lift shall be designed & manufactured as per
latest version of EN-81 standards, EN-81-20, EN 81-50. The safety components, such as,
progressive safety gear, door locking devices, buffers, over speed governor, car over travel
protection system, door inter-locking device, pre and final limit switches of the proposed
lift shall be in conformity with latest version of BNBC, BS EN-81/EN-81(Lift Directive
95/16/EC) / DIN / VDE / ANSI/ASME A17.1 / JIS standards & safety codes. Installation,
testing and Commissioning of the lift shall also be in conformity with the above standards
& codes.
Certificates issued by internationally recognized authorities like TUV / DNV for the
product(s) (At least the safety components such as, progressive safety gear, door locking
devices, buffers, over speed governor, car over travel protection system, door inter-locking
device, pre and final limit switches) of the manufacturer(s) as per above mentioned relevant
valid regulations, codes and standards shall have to be submitted by the bidder.
The above certificates shall have to be authenticated by the Chamber of Commerce /
Ministry of Commerce / Foreign Ministry of the manufacturing Country. Relevant ISO
certificate(s) of the manufacturer including lift ride quality measurement ISO 18738/5 shall