| Eligibility of Tenderer : |
As Per TDS and Last Amendment of PPR-2008 and Last Circular of CPTU.
The Minimum number of Years of general experience of the Tenderer in the construction works as Prime Contractor or Subcontractor or Management Contractor Shall be 05 (Five) years. Years counting backward from the date of publication of IFT in the e-GP website.
The minimum specific experience (including Production tubewell) as a Prime Contractor or Subcontractor or Management Contractor in construction works of at least 01(One) contract(s) of similar nature, complexity and methods/construction technology successfully completed within the last 05(Five) years, each with a value of at least Tk.1,25,00,000.00(One Crore and Twenty Five Lac). Years counting backward from the date of publication of IFT in the e-GP website.
The required average annual construction turnover shall be greater than Tk . 2,00,00,000.00(Two Crore) over the last 05(Five) years. Years counting backward from the date of publication of IFT in the e-GP website.
The minimum amount of liquid assets or working capital or credit facilities of theTenderer shall be Tk. 70,00,000.00(Seventy Lac).
The Quoted Tender will be non-responsive if the Quoted price is more than 10 percent less or 10 percent above of the official cost estimate.
Without Containing PE's Memo & Name, Work Order Amount, completed amount, Completion Date, official ref no./memo, e-Mail (if Possible), Experience Certificate/Payment Certificate will be disregarded for evaluation process.
Bank Statement must be within Publishing date to closing date of Tender or Credit facility must be in CPTU Prescribed form otherwise the Tender would be considered as Non-Responsive.
|
| Brief Description of Works : |
Installation of 8 (Eight) Nos. 38 mm dia uPVC Test Tubewell, 4 (Four) Nos 150 x 350 mm dia uPVC Production well, Construction of 04 (Four) Nos Pump house with Boundary Wall & Electric Power Connection, Supply and Installation of 04 (Four) Nos Submersible Pump motor set with Column Pipe and Electric Panel Board with necessary accessories and 04 (Four) Nos Electric Transformer and other Electrical materials at (1). Adjacent to Gylekata Eidgah Math, (2). Adjacent to Kuliarchar 1 No. Govt. Primary School, (3). Adjacent to Asrabpur C&B Road of Kuliarchar Poura area(3 Nos PTW, 3 Nos PH, 3 Nos SP & 3 Nos Transformer) & (4). Asutia Gangpara of Karimganj poura area(1 No. PTW, 1 No. PH, 1 No. SP & 1 Nos Transformer) of Kishoreganj District under Water supply & Environmental Sanitation including Faecal Sludge Management Project in 32 Pourashavas During the 2018-2019 Financial Year.
|