View IFT /PQ / REOI / RFP / PPS Notice Details
|
Amendment / Corrigendum No. : 1
|
|
| Amendment / Corrigendum Text : | CORRIGENDUM-1: |
| Field Name | Old Value | New Value | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Document last selling date & time | 30/12/2019 16:30 | 13/01/2020 16:30 | ||||||||||||||||||||||||
| Eligibility of Consultant | As per Tender Data sheet & Tender Documents. |
As per Tender Data sheet & Tender Documents. |
||||||||||||||||||||||||
| Opening Date & Time | 31/12/2019 12:00 | 14/01/2020 12:00 | ||||||||||||||||||||||||
| Last date & time for Tender/Proposal Security Submission | 30/12/2019 10:30 | 14/01/2020 10:30 | ||||||||||||||||||||||||
| Closing Date & Time | 31/12/2019 12:00 | 14/01/2020 12:00 | ||||||||||||||||||||||||
| TDS/PDS--C. Qualification Criteria-- |
a. The required average annual construction turnover shall be greater than Tk 1,60,00,000.00 (One Crore Sixty Lakh) over the last 5 years. (years counting backward from the date of publication of IFT in the newspaper) The minimum amount of liquid assets or working capital or credit facilities of the Tenderer shall be Tk 1,80,00,000.00 (One Crore Eighty Lakh). |
a. The required average annual construction turnover shall be greater than Tk 1,60,00,000.00 (One Crore Sixty Lakh) over the last 5 years. (years counting backward from the date of publication of IFT in the newspaper) The minimum amount of liquid assets or working capital or credit facilities of the Tenderer shall be Tk 1,80,00,000.00 (One Crore Eighty Lakh).
The minimum amount of liquid assets or working capital or credit facilities of the Tenderer must satisfy the assessment of Financial Resources Availability as mentioned in Annexure: 5-4. |
||||||||||||||||||||||||
| TDS/PDS--C. Qualification Criteria-- | A Construction Project Manager, Engineer, and other key staff shall have the following qualifications and experience:
|
The following part is included after the table of this clause: A Construction Project Manager, Engineer, and other key staff shall have the following qualifications and experience:
|
||||||||||||||||||||||||
| TDS/PDS--C. Qualification Criteria-- | The minimum qualification requirements of Leading Partner and other Partner(s) of a JVCA shall be as follows : Leading Partner : 51% and other partner : 49% [it is suggested that the PE adheres to the above proportion of minimum qualifying requirements to meet the specific procurement needs. Percent share of business of the JVCA partners shall not be taken into account in determining the qualification of a JVCA] |
The minimum qualification requirements of Leading Partner and other Partner(s) of a JVCA shall be as follows : Leading Partner : 51% and other partner : 49% [it is suggested that the PE adheres to the above proportion of minimum qualifying requirements to meet the specific procurement needs. Percent share of business of the JVCA partners shall not be taken into account in determining the qualification of a JVCA] Annexure: 5-1, Annexure: 5-2, Annexure: 5-3 & Annexure: 5-4 shall be the part of Tenderer Information and JVCA Partner Information[ENCLOSED] |
||||||||||||||||||||||||
| TDS/PDS--D. Tender Preparation-- |
The Tenderer shall submit with its Tender, the following additional documents: (h) Audited Financial Report (Last 3 Years). |
The Tenderer shall submit with its Tender, the following additional documents: (h) Audited Financial Report (Last 3 Years).
IN ADDITION; The Tenderer shall submit with its technical offer the following additional documents:
2). Tenderer shall have to submit the information of all ongoing turnkey contract(s) in govt. entities under power sector of Bangladesh in the format attached as Annexure: 5-2 with supporting document (Acceptance of NOA/Contact agreement) along with the upto date progress cum work quality certificate from end user. |
||||||||||||||||||||||||
| Brief Description of Goods,Works or Service | Construction and Renovation works of 11 kV, 11/0.4kV and 0.4kV Line (including installation of 11/0.4kV distribution transformer) at Sales & Distribution Division, BPDB, Fulpur, Mymensingh under Power Distribution System Development Project, Mymensingh Zone. |
Construction and Renovation works of 11 kV, 11/0.4kV and 0.4kV Line (including installation of 11/0.4kV distribution transformer) at Sales & Distribution Division, BPDB, Fulpur, Mymensingh under Power Distribution System Development Project, Mymensingh Zone. |
| Amendment / Corrigendum/ Addendum No. : | 1 | ||||
| S. No. | File Name | File Description | File Size (in KB) |
||
|---|---|---|---|---|---|
| 1 | ANNEXURES-5.1 TO 5.4.pdf | ANNEXURES-5.1 TO 5.4 | 180898 | ||