View IFT /PQ / REOI / RFP / PPS Notice Details
|
Amendment / Corrigendum No. : 1
|
|
| Amendment / Corrigendum Text : | Notice |
| Field Name | Old Value | New Value | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Completion Date(Lot No : 1) | 31/12/2024 | 28/11/2024 | ||||||||
| Eligibility of Consultant | The invitation for tender is open to all eligible Tenderers/Contractor who have comply the following condition:- |
The invitation for tender is open to all eligible Tenderers/Contractor who have comply the following condition:- (a) The minimum number of years of general experience of the tenderer in the electrical works prime contractorshall be 5 (five) years. (b) The minimum specific experience as a prime contractor in providing, installation testing &Commissioning minimum 02 Nos 500 KVA sub-station equipment & 02 Nos 150 KVA generator with H.T & L.T cable and necessary related accessories at least one contract successfully completed within the last 5(five) years with a value of at least Tk 300.00 (Three hundred) lac in Govt./Semi-Govt./Autonomous organization. (c) The tenderers must possess up-to-date trade and VAT registration certificate, income TAX clearance certificate, ABC Contractor’s and supervisory license. (d) The tenderers shall have a minimum average annual construction turnover Tk 1060.00 (One thousand sixty) lac over the last 5 (five) years. Payment certificates of works contract in progress or completed under Govt./Semi-Govt./Autonomous organization must be submitted along with tender in support of average annual construction turnover. (e) The minimum amount of liquid assets i.e.,working capital or credit facilities as PW3-7 format of the Tenderers shall be Tk 220.00 (Two hundred twenty) lac. Document submitted along with the tender must be issued by any scheduled bank in between tender publication and submission date in e-GP portal. (f) The minimum tender capacity shall be Tk.330.00 (Three hundred thirty) lac. In case of JV tender capacity required for leading and other partners shall be as described in TDS. (g) The procuring entity reserves the right to accept or reject all tenders and no claims will be accepted in this regard. |
||||||||
| PCC 73. Liquidated Damages73.1 Liquidated Damages |
|
|
||||||||
| Start Date(Lot No : 1) | 31/07/2024 | 01/07/2024 | ||||||||
| TDS/PDS--C. Qualification Criteria-- | The minimum number of years of general experience of the Tenderer in the construction works as Prime Contractor or Subcontractor or Management Contractor shall be 5(five) years. |
(i) The minimum number of years of general experience of the Tenderer in the construction works as Prime Contractor shall be 5(five) years. (ii) The minimum specific experience as a prime contractor in providing, installation testing &Commissioning minimum 02 Nos 500 KVA sub-station equipment & 02 Nos 150 KVA generator with H.T & L.T cable and necessary related accessoriesat least one contract successfully completed within the last 5(five) years with a value of at least Tk.300.00 (Three hundred) lac in Govt./Semi-Govt./Autonomous organization. |
||||||||
| TDS/PDS--C. Qualification Criteria-- | The minimum capacity shall be: 310 lac |
The minimum tender capacity shall be Tk.330.00 (Three hundred thirty) lac. In case of JV tender capacity required for leading and other partners shall be as described in TDS. |
||||||||
| TDS/PDS--C. Qualification Criteria-- | The required average annual construction turnover shall be greater than Tk 265 lac over the last 5 years. |
(a) The tenderers shall have a minimum average annual construction turnover Tk 1060.00 (One thousand sixty)lac over the last 5 (five) years. Payment certificates of works contract in progress or completed under Govt./Semi-Govt./Autonomous organization must be submitted along with tender in support of average annual construction turnover. (b) The minimum amount of liquid assets i.e.,working capital or credit facilities as PW3-7 format of the Tenderers shall be Tk 220.00 (Two hundred twenty) lac. Document submitted along with the tender must be issued by any scheduled bank in between tender publication and submission date in e-GP portal. |
||||||||
| TDS/PDS--C. Qualification Criteria-- | The Nominated Subcontractor(s) named [insert name(s)] shall execute the following specific components of the proposed Works:N/A
|
The Nominated Subcontractor(s) named [insert name(s)] shall execute the following specific components of the proposed Works:N/A
|
||||||||
| Brief Description of Goods,Works or Service | Construction of 15 Nos 14-storied residential flat Building at Section-09,Mirpur,Dhaka (2nd phase) (Sub-head: Supplying, installation, testing & commissioning of 03 Nos, 630 KVA Indoor Electric Sub-Station & 02 Nos, 150 KVA & 01 No, 400 KVA Diesel generator (for Building No: 19,community Bldg & STP/WTP.) |
Construction of 15 Nos 14-storied residential flat Building at Section-09,Mirpur,Dhaka (2nd phase) (Sub-head: Supplying, installation, testing & commissioning of 03 Nos, 630 KVA Indoor Electric Sub-Station & 02 Nos, 150 KVA & 01 No, 400 KVA Diesel generator (for Building No: 19,community Bldg & STP/WTP.) |